Skip to content Skip to navigation menu

Your Selected Vehicle

Brands

Show More Show Less

Price

Parts for your 2020 Mitsubishi Eclipse cross-Tx valve

Sort by

Explore 4WD & Adventure

Showing 1 - 39 of 267 products

2020 Mitsubishi Eclipse Cross TX Valve (TXV): What it does and how to look after it

Based on technical references — including the Mitsubishi Motors Service Manual (Heating & Air Conditioning, Group 55A) for the Eclipse Cross (2018–2020 GK series) and the Mitsubishi ASA/parts catalogue section for the Heater Unit & Evaporator — the 2020 Mitsubishi Eclipse Cross is fitted with a thermostatic expansion valve (TXV) mounted at the evaporator.

On the 2020 Eclipse Cross, the TX valve is the brains of the air‑con’s refrigerant flow. It meters liquid refrigerant into the evaporator and constantly tweaks that flow to maintain the right superheat, keeping cabin temps stable without freezing the evaporator. It sits where the refrigerant lines meet the evaporator housing (at the firewall area), paired with a receiver‑drier in the condenser — a common layout for modern R‑134a or R‑1234yf systems. The vehicle’s under‑bonnet label confirms the exact refrigerant for the market.

There’s no routine “maintenance” for a TXV, but clean system conditions and correct charge keep it happy. During scheduled A/C service (every couple of years is sensible in Aussie and Kiwi conditions), a workshop should:

  • Check vent temps and pressure readings to confirm the valve is controlling superheat properly.
  • Inspect for leaks at the valve block and line fittings, replace O‑rings if disturbed.
  • Recover, vacuum and recharge to the precise fill mass on the bonnet label — no guesswork or top‑ups.
  • Add the correct PAG oil type/amount if components have been replaced, and consider a new receiver‑drier whenever the system’s opened.

Tell‑tale signs of a TXV issue include weak cooling at idle but cold on the highway, frost or sweating on the valve/lines, rapid cycling, or a hissing/whistling at the evaporator. Of course, those symptoms can also come from low charge, a blocked cabin filter, a dirty condenser, or a failing compressor — so proper diagnosis matters.

Replacement on the Eclipse Cross is a straightforward but licensed job. Refrigerant must be recovered by an ARCtick‑licensed technician in Australia or a certified handler in New Zealand. Access typically involves working at the firewall connection to the evaporator housing, the valve is unbolted, O‑rings renewed, and everything torqued to spec before evacuation and recharge. Because stickiness or debris can jam a TXV, any contamination (burnt oil, black sludge, desiccant beads) calls for broader cleanup — think flushing appropriate lines, replacing the receiver‑drier, and verifying compressor health.

For owners, the best way to extend TXV life is simple: keep the cabin filter fresh, make sure the condenser isn’t packed with bugs and road grime, run the A/C regularly to move oil through the system, and use reputable workshops that charge by weight, not by “feel”. That keeps the Eclipse Cross cool through scorching Aussie summers and four‑seasons Kiwi days.

Q: Does the 2020 Mitsubishi Eclipse Cross actually have a TX valve?

Yes. Mitsubishi’s service documentation and the Mitsubishi ASA parts catalogue list an A/C expansion (TX) valve attached to the evaporator on 2018–2020 Eclipse Cross models. It’s part of the standard HVAC design for this vehicle.

Q: What are common signs the TX valve needs attention on a 2020 Eclipse Cross?

Look for inconsistent vent temps, weak cooling at idle, visible frost on the valve or suction line, rapid compressor cycling, or a noticeable hiss at the evaporator. Because these symptoms can overlap with low refrigerant or airflow issues, a pressure/temperature test by a licensed air‑con tech is the way to pinpoint the fault.

Q: How long and how much to replace the TX valve in Australia or New Zealand?

Expect roughly 1.5–3.5 hours depending on access and whether other components (like the receiver‑drier) are replaced. Parts are typically modest, but the job includes recovery, vacuum and precise recharge. Ballpark totals vary by workshop and refrigerant type, a proper quote after diagnosis is best.

{ "@context": "https://schema.org", "@type": "FAQPage", "mainEntity": [ { "@type": "Question", "name": "Does the 2020 Mitsubishi Eclipse Cross actually have a TX valve?", "acceptedAnswer": { "@type": "Answer", "text": "Yes. Mitsubishi’s service documentation and the Mitsubishi ASA parts catalogue list an A/C expansion (TX) valve attached to the evaporator on 2018–2020 Eclipse Cross models. It’s part of the standard HVAC design for this vehicle." } }, { "@type": "Question", "name": "What are common signs the TX valve needs attention on a 2020 Eclipse Cross?", "acceptedAnswer": { "@type": "Answer", "text": "Look for inconsistent vent temps, weak cooling at idle, visible frost on the valve or suction line, rapid compressor cycling, or a noticeable hiss at the evaporator. Because these symptoms can overlap with low refrigerant or airflow issues, a pressure/temperature test by a licensed air‑con tech is the way to pinpoint the fault." } }, { "@type": "Question", "name": "How long and how much to replace the TX valve in Australia or New Zealand?", "acceptedAnswer": { "@type": "Answer", "text": "Expect roughly 1.5–3.5 hours depending on access and whether other components (like the receiver‑drier) are replaced. Parts are typically modest, but the job includes recovery, vacuum and precise recharge. Ballpark totals vary by workshop and refrigerant type, a proper quote after diagnosis is best." } } ]}