Your Selected Vehicle
Parts for your 2015 Subaru Exiga-Ac condensor
Mahle Air Conditioning Condenser Parallel Flow Inlet Pad Outlet Pad - AC 659 000S
Fitment Notes:
Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - CNX923
Fitment Notes:
Doowon Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - CNX968G
Fitment Notes:
REDDOT Condenser Parallel Flow Inlet #8 MIOR Outlet #6 MIOR - RD474990P
Fitment Notes:
Sanden Air Conditioning Condenser Parallel Flow Inlet #8 MIOR Outlet #6 MIOR - CNX413
Fitment Notes:
Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - CNX7750
Fitment Notes:
Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - CNX845
Fitment Notes:
Explore 4WD & Adventure
REDDOT Condenser Assembly Inlet #8 MIOR Outlet #6 MIOR - R62601P
Fitment Notes:
REDDOT Condenser Assembly Inlet #8 MIOR Outlet #6 MIOR - R4500824P
Fitment Notes:
REDDOT 24V Red Dot Roof Top Condenser Assembly 24V - R9725324P
Fitment Notes:
REDDOT Condenser Assembly Inlet #8 MIOR Outlet #6 MIOR - R61600P
Fitment Notes:
REDDOT Condenser Tube and Fin Inlet #8 MIOR Outlet #6 MIOR - RD435860P
Fitment Notes:
MAHLE Condenser Tube and Fin Inlet #8 MIOR Outlet #6 MIOR - AC684000P
Fitment Notes:
MAHLE Condenser Parallel Flow Inlet Pad Outlet Pad - AC756000P
Fitment Notes:
OEX Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - CNX974
Fitment Notes:
REDDOT 24V Remote Mount Condenser Assembly Inlet #8 MIOR Outlet #6 MIOR - R9730024P
Fitment Notes:
REDDOT Condenser Assembly Inlet #8 MIOR Outlet #6 MIOR - R97201224P
Fitment Notes:
REDDOT Condenser Serpentine Inlet #8 MIOR Outlet #6 MIOR - R6260124P
Fitment Notes:
Denso Air Conditioning Condenser Parallel Flow Inlet Pad Outlet Pad - CNX9370
Fitment Notes:
VALEO Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - 814386
Fitment Notes:
REDDOT Condenser Tube and Fin Inlet #8 MIOR Outlet #6 MIOR - RD451220P
Fitment Notes:
Reddot Condenser Parallel Flow Inlet #8 MIOR Outlet #6 MIOR - RD453780P
Fitment Notes:
OEX Condenser Serpentine Inlet #8 MIOR Outlet #6 MIOR - CNX01067
Fitment Notes:
Reddot Condenser Tube and Fin Inlet #8 MIOR Outlet #6 MIOR - RD437240P
Fitment Notes:
Reddot Condenser Tube and Fin Inlet #8 MIOR Outlet #6 MIOR - RD444400P
Fitment Notes:
REDDOT Condenser Parallel Flow Inlet #8 MIOR Outlet #6 MIOR - RD475430P
Fitment Notes:
Denso First Time Fit Air Conditioning Condenser Parallel Flow Inlet Pad Outlet Pad - CNX985
Fitment Notes:
OEX Condenser Tube and Fin Inlet #8 MIOR Outlet #6 MIOR - CNX01065
Fitment Notes:
DENSO Condenser Parallel Flow Inlet Pad Outlet Pad - Fan Assembly Included
Fitment Notes:
REDDOT Condenser Serpentine Inlet #8 MIOR Outlet #6 MIOR - CNX01030
Fitment Notes:
REDDOT Condenser Tube and Fin Inlet #8 MIOR Outlet #6 MIOR - RD450450P
Fitment Notes:
Denso Air Conditioning Condenser Parallel Flow Inlet Pad Outlet Pad
Fitment Notes:
Understanding the AC Condenser on a 2015 Subaru Exiga
The 2015 Subaru Exiga, like many modern vehicles equipped with air conditioning systems, uses an AC condenser as a crucial component to keep the cabin comfortable during Australia's hot days. The AC condenser plays a vital role in the vehicle's cooling system, ensuring that the air conditioning works efficiently and reliably.
So what exactly does the AC condenser do on a 2015 Subaru Exiga? Simply put, the AC condenser acts as a heat exchanger. When you turn on the air conditioning in your Exiga, the refrigerant inside the AC system circulates under high pressure as a hot gas. The condenser's job is to dissipate this heat to the outside air, turning the refrigerant from a gas into a cool liquid. This cooler liquid refrigerant then flows through the system, eventually cooling the air that blows through your car's vents.
Positioned right at the front of the vehicle, often in front of the radiator, the condenser needs to be well exposed to airflow. This is so it can effectively get rid of the heat it collects from the refrigerant. If this component isn't working properly, the AC system won't be able to produce cold air, which can make driving in the Australian heat less bearable.
Regular maintenance of the AC condenser in the Subaru Exiga is vital for keeping your car's air conditioning in tip-top shape. Over time, debris such as dust, leaves, and bugs can clog the condenser's fins, reducing its ability to dissipate heat. This blockage means the refrigerant will stay warmer than it should, leading to poor AC performance or even system damage.
When servicing the AC system in a 2015 Subaru Exiga, mechanics will often check the condenser for physical damage or blockages, particularly if the AC is not cooling well. The fins can be delicate, so care must be taken when cleaning or repairing to avoid bending or breaking them. A blocked or damaged condenser can cause the AC system's high pressure to increase, which risks damage to other components such as the compressor.
If there is a noticeable leak around the condenser, it usually indicates it needs to be replaced. Leaks let the refrigerant escape, causing the AC to lose pressure and eventually stop cooling. Given the specialised nature of refrigerants used in air conditioning systems, a leaking condenser is not something to ignore. A professional AC technician will identify leaks using UV dye or electronic leak detectors.
When it comes to replacing the AC condenser on a 2015 Subaru Exiga, it's important to ensure that genuine or high-quality aftermarket components are used. The part needs to match the exact specifications of the Exiga's system, otherwise the AC might not perform as it should. Replacement involves evacuating the refrigerant safely, removing the old condenser, installing the new one, and then recharging the system with the correct amount and type of refrigerant.
Preventative maintenance is the best way to avoid unexpected AC problems with the condenser. This includes regular servicing checks, especially before summer when you're likely to use the air conditioning the most. Keeping the front of the car clear from obstructions like leaves or park dust can help maintain airflow through the condenser.
Owners of the Subaru Exiga should also turn on their air conditioning system occasionally, even outside of summer. This keeps the system lubricated and prevents seals within the AC components from drying out and cracking, which can impact the condenser as well.
In short, the AC condenser on the 2015 Subaru Exiga is a key part of the air conditioning system, tasked with cooling the refrigerant to deliver fresh, cool air inside the cabin. Proper care, maintenance checks, and prompt repairs when needed will help keep the AC condenser working efficiently for many kilometres, contributing to a comfortable driving experience in all kinds of weather.