Your Selected Vehicle
Parts for your 2007 Honda Stream-Ac condensor
Denso First Time Fit Air Conditioning Condenser Parallel Flow Inlet Pad Outlet Pad - CNX985
REDDOT Condenser Tube and Fin Inlet #8 MIOR Outlet #6 MIOR - RD464100P
Denso Air Conditioning Condenser Parallel Flow Inlet Pad Outlet Pad
REDDOT Condenser Tube and Fin Inlet #6 MIOR Outlet #6 MIOR - RD440691P
Denso Air Conditioning Condenser Parallel Flow Inlet Pad Outlet Pad - CNX9370
Explore 4WD & Adventure
OEX Conditioner Condenser Parallel Flow Inlet #8 MIOR Outlet #6 MIOR - CNX307
REDDOT Condenser Parallel Flow Inlet Pad Outlet Pad - CNX01061
REDDOT Condenser Parallel Flow Inlet Pad Outlet Pad - RD475520P
REDDOT 24V Red Dot Roof Top Condenser Assembly 24V - R9725324P
Sanden Air Conditioning Condenser Parallel Flow Inlet #8 MIOR Outlet #6 MIOR
Hanon Air Conditioning Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - CNX01015
Doowon Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - CNX01060
REDDOT Condenser Assembly Inlet #8 MIOR Outlet #6 MIOR - R97201224P
Doowon Air Conditioning Condenser Parallel Flow Inlet Pad Outlet Pad - CNX148
REDDOT Condenser Serpentine Inlet #8 MIOR Outlet #6 MIOR - RD475440P
Reddot Condenser Tube and Fin Inlet #8 MIOR Outlet #6 MIOR - RD444400P
Hanon Air Conditioning Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - CNX996
Doowon Air Conditioning Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - CNX01018
Denso Air Conditioning Condenser Parallel Flow Inlet Pad Outlet Pad
REDDOT Condenser Parallel Flow Inlet #8 MIOR Outlet #6 MIOR - RD474990P
Doowon Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - CNX993
Doowon Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - CNX969G
Doowon Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - CNX968G
OEX Condenser Parallel Flow (Subcooled) Inlet Pad Outlet Pad - CNX415
OEX Condenser Parallel Flow Inlet #8 MIOR Outlet #6 MIOR - CNX424
OEX Condenser Parallel Flow Inlet #8 MIOR Outlet #6 MIOR - CNX01058
OEX Condenser Tube and Fin Inlet #8 MIOR Outlet #6 MIOR - CNX01065
2007 Honda Stream AC Condenser — what it does and how to look after it
Yes, the 2007 Honda Stream is fitted with an AC condenser. This is confirmed by Honda’s RN6–RN9 Service Manual HVAC section, the Honda Electronic Parts Catalogue (which lists a “Condenser Assy., Air Conditioner” for 2007 Stream variants), and major aftermarket catalogues from OEM suppliers like Denso and Nissens. So the condenser is absolutely relevant on this model.
On the 2007 Stream, the condenser sits in front of the radiator and sheds heat from the high‑pressure refrigerant coming from the compressor. As air moves through its fins (helped by the condenser/radiator fans), hot vapour condenses back into a liquid so the cabin can get properly cold. If the condenser is blocked, bent, or leaking, expect weak cooling at idle, compressor cycling, higher than normal system pressures, or oily residue on the fins.
As part of routine servicing, a visual check goes a long way. Road grime, bugs, and bent fins are common culprits. In coastal areas, corrosion can creep in too. Keeping the fins clean with gentle low‑pressure water (never a harsh pressure washer) helps airflow. If fins are slightly bent, a proper fin comb can tidy them up. Any stone damage or green UV dye traces around the tanks or joints points to a leak that needs attention.
When replacement’s on the cards, it’s a front‑bumper‑off job on most Stream variants. The system must be recovered by a licensed tech (it’s R‑134a from factory on 2007 models). New O‑rings should be fitted, lightly lubricated with the specified PAG oil (Honda ND‑OIL 8), and connections tightened to the torque in the service manual. Many Hondas of this era have the receiver/drier integrated into the condenser side tank, so the drier should be renewed whenever the system’s opened or the condenser is replaced. After reassembly, the system needs a proper vacuum (to boil off moisture), then a charge by weight to the exact figure on the under‑bonnet label—don’t “top up by feel”.
Good habits: have the air‑con run for 10–15 minutes every week, even in winter, to circulate oil through seals. Keep the cabin filter fresh so airflow across the evaporator is spot on, which helps the whole system—including the condenser—work efficiently and last longer.
- Clean fins gently, avoid bending.
- Replace O‑rings and the drier when the system is opened.
- Vacuum, then charge by weight to the label spec, use the correct PAG oil.
- Inspect for leaks, corrosion, and impact damage during regular services.
Popular questions about the 2007 Honda Stream AC condenser
Does the 2007 Honda Stream use R‑134a or R‑1234yf?
From factory it uses R‑134a. Always verify the refrigerant type and charge amount on the under‑bonnet label, follow that label over any generic guide, especially after engine bay swaps or previous AC work.
Is the receiver/drier separate on this model?
On many 2007 Stream variants the drier is integrated into the condenser’s side tank. That means when the condenser is replaced, the drier is effectively renewed. If the system’s been opened, the drier element should be replaced to protect the compressor and expansion valve.
How long should a condenser last?
There’s no set interval, they’re replaced on condition. With clean fins, intact splash shields, and healthy fans, they can last years. Stone strikes, corrosion, or internal blockage are the usual reasons for change.