Your Selected Vehicle
Parts for your 1999 Daihatsu Gran move-Batteries
Narva Battery Master / Isolation Switch Plastic With Removable Key (Contacts Rated 100A at 12V) - 61038BL
Narva Sealed Rocker Switch Off/On SPDT 12V Blue Illuminated LED Light Bar Symbol (Contacts Rated 20A @ 12V) - 63145BL
Explore 4WD & Adventure
Narva Sealed Rocker Switch Momentary On/Off/Momentary On DPDT 12V Blue Illuminated Winch Symbol (Contacts Rated 20A @ 12V Only) - 63148BL
Narva Heavy Duty Toggle Switch Momentary On/Off/Momentary On DPDT (Contacts Rated 25A @ 12V) - 60068BL
Narva Mitsubishi Style Sealed Push Switch Off/On SPDT 12V Blue LED Illuminated Driving Lights Symbol (Contacts Rated 3A @ 12V) - 63364BL
Narva OE Style Sealed Push Switch Off/On SPDT 12V Blue LED Illuminated Driving Lights Symbol (Contacts Rated 3A @ 12V) - 63316BL
Narva Sealed Rocker Switch Off/Momentary On SPST 12V Amber Illuminated (Contacts Rated 20A @ 12V) - 63126BL
Narva Sealed Rocker Switch Off/On SPDT 12V Blue Illuminated Beacon Symbol (Contacts Rated 20A @ 12V) - 63147BL
Narva Rotary Battery Master / Isolator Switch With Removeable Keyed Knob (Contacts Rated 100A @ 12V) - 61036BL
Narva Battery Master / Isolation Switch Plastic With Removable Key (Contacts Rated 100A at 12V) - 61038
Narva Sealed Rocker Switch Off/On SPDT 12V Blue Illuminated Driving Lights Symbol (Contacts Rated 20A @ 12V) - 63132BL
Narva Automotive/Marine Battery Master / Isolation Switch (Contacts Rated 300A @ 12V) - 61044BL
Narva 4 Position Rotary Battery Master / Isolation Switch (Contacts Rated 300A @ 12V) - 61084BL
Narva Rotary Battery Master / Isolator Switch With Removeable Keyed Knob (Contacts Rated 100A 12V) - 61036
Narva Heavy Duty Battery Master / Isolation Switch with Removable Key (Contacts Rated 250A @ 12V) - 61050
1999 Daihatsu Gran Move batteries
The 1999 Daihatsu Gran Move is factory-fitted with a 12‑volt lead‑acid starter battery. This is confirmed by technical sources including the Daihatsu Gran Move/Pyzar Owner’s Manual (Electrical System—Battery section), the Daihatsu Service/Workshop Manual for the M1xx series (wiring diagrams and charging system), and Australian/NZ battery fitment catalogues from Century/Yuasa and Exide. These references all specify a conventional 12 V SLI (starting, lighting, ignition) battery for this model.
On a Gran Move, the battery’s job is bigger than just cranking the engine. It stabilises voltage for the ECU, fuel pump, ignition and sensors, powers lights and accessories with the engine off, and acts as a buffer when electrical loads spike. If it’s weak, expect slow cranking, odd dash warnings, or rough idle after starts. Keeping it healthy makes the car easier to live with, especially if it does short trips around town.
When it’s time for servicing, a quick battery check under the bonnet is worth doing. A fully charged unit rests around 12.6 V, with the engine running, expect roughly 13.8–14.5 V across the terminals as the alternator charges. Many Gran Moves run happily for years, but most lead‑acid batteries in Australian and New Zealand conditions last about 3–5 years. Heat, lots of short runs, and long periods parked can shorten that.
Replacement is straightforward, but a few tips keep it tidy. Match the case size and terminal layout to the original tray and leads, and choose suitable cold‑cranking amps (CCA) for reliable starts. If the battery is a serviceable design, keep electrolyte above the plates with distilled water, if it’s maintenance‑free, just check the sight indicator if fitted. Use a memory saver if you want to keep radio presets, wear eye and hand protection, and dispose of the old unit responsibly—most parts stores will recycle it for you.
After reconnecting, let the engine idle for a few minutes so the ECU can relearn basics. If the battery light stays on with the engine running, that’s usually the charging system—check the alternator belt and output rather than blaming the battery.
- Keep terminals clean and tight, neutralise corrosion with a bicarb-and-water mix.
- Secure the hold‑down clamp so vibration doesn’t fatigue the plates.
- If the car sits, throw on a smart charger to avoid sulphation.
- Have the battery load‑tested before winter or a long trip.
What battery type and size suits a 1999 Daihatsu Gran Move?
It uses a 12 V lead‑acid SLI battery in a compact JIS‑style case commonly fitted to small Japanese MPVs of the era. Exact case size, terminal layout and CCA can vary, so match what’s in the tray or check an AU/NZ fitment guide to confirm dimensions, terminal position and capacity before buying.
How long should the battery last?
Typically 3–5 years in local conditions. Lots of short trips, high heat, or infrequent use will shorten life. Annual testing during servicing helps catch a weak battery before it leaves the Gran Move stranded.
Why is the battery warning light on while driving?
That lamp indicates a charging issue, not just the battery. Check the alternator belt and measure charging voltage (around 13.8–14.5 V at the terminals). If it’s low or fluctuating, have the alternator and wiring inspected before replacing the battery.